The document provides detailed technical specifications for the Channel MS 41 profiles. It includes dimensional data (width, height, thickness), section properties (section modulus, moment of inertia, radius of gyration), and mechanical performance values such as maximum point carrying capacity, torsional moment, and cross-sectional area. Both single and double channel configurations are covered, with notes on installation requirements for short sections. All values refer to slotted channels.
PDF (0.20MB)
This document provides permissible load data for Channel MS 41-75/75/3.0 under centrical load application. It includes tables listing allowable loads (in Newtons) for span lengths from 20 cm up to 600 cm for both single and double channel configurations. The calculations consider channel slots and dead weight, based on RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). Slot pattern IV is specified for installation.
PDF (0.16MB)
This document provides permissible load data for Channel MS 41-75/65/3.0 under centrical load application. It includes tables listing allowable loads (in Newtons) for span lengths from 20 cm up to 600 cm for both single and double channel configurations. The calculations consider channel slots and dead weight, based on RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). Slot pattern IV is specified for installation.
PDF (0.16MB)
This document provides permissible load data for Channel MS 41/62/2.5 under centrical load application. It includes tables listing allowable loads (in Newtons) for span lengths from 20 cm up to 600 cm for both single and double channel configurations. The calculations consider channel slots and dead weight, based on RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). Slot pattern III is specified for installation.
PDF (0.10MB)
This document provides permissible load data for Channel MS 41/52/2.5 under centrical load application. It includes tables listing allowable loads (in Newtons) for span lengths from 20 cm up to 600 cm for both single and double channel configurations. The calculations consider channel slots and dead weight, based on RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). Slot pattern III is specified for installation.
PDF (0.10MB)
This document provides permissible load data for Channel MS 41/45/2.5 under centrical load application. It includes tables listing allowable loads (in Newtons) for span lengths from 20 cm up to 600 cm for both single and double channel configurations. The calculations consider channel slots and dead weight, based on RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). Slot pattern III is specified for installation.
PDF (0.10MB)
This document provides permissible load data for Channel MS 41/41/2.5 under centrical load application. It includes tables listing allowable loads (in Newtons) for span lengths from 20 cm up to 600 cm for both single and double channel configurations. The calculations consider channel slots and dead weight, based on RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). Slot pattern III is specified for installation.
PDF (0.12MB)
This document provides permissible load data for Channel MS 41/41/2.0 under centrical load application. It includes tables listing allowable loads (in Newtons) for span lengths from 20 cm up to 600 cm for both single and double channel configurations. The calculations consider channel slots and dead weight, based on RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). Slot pattern III is specified for installation.
PDF (0.11MB)
This document details permissible loads for Channel MS 41/31/2.0 under centrical load application. It provides a table of allowable loads (in Newtons) for span lengths from 20 cm to 500 cm. The calculations account for channel slots and dead weight, based on RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). Slot pattern III is specified for installation.
PDF (0.08MB)
This document provides permissible load data for Channel MS 41/21/2.0 under centrical load application. It includes tables showing allowable loads (in Newtons) for different span lengths (20 cm to 500 cm) for both single and double channel configurations. The calculations consider channel slots and dead weight, following RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). Installation details such as slot pattern III are also referenced.
PDF (0.09MB)
This document provides permissible load data for Channel MS 41/21/1.5 under centrical load application. It includes a table showing allowable loads (in Newtons) for different span lengths (20 cm to 300 cm), considering channel slots and dead weight. Calculations follow RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). Slot pattern II and relevant dimensions are also indicated.
PDF (0.09MB)
This document provides permissible load data for Channels MS 27/15, MS 27/25, and MS 27/37 under centrical load application. It includes tables listing allowable loads (in Newtons) for span lengths from 20 cm up to 300 cm. The calculations consider channel slots and dead weight, based on RAL-GZ 655-C standards, with limits for stress (σ ≤ 185 N/mm²) and deflection (f ≤ L/200). These profiles belong to the Pressix CC 27 Assembly System.